Click a tab below for more information:
-
eScan | Verification Service Technology (VST)
Fastest and only Tamperproof Verification Technology on the Market.
By investing in the Enalasys Verification Service Technology(VST), it has never been as easy and efficient to diagnose and correct residential and commercial HVAC units.
With this evolutionary, industry proven and tamper-proof technology, software automatically populates forms with data once a test is performed correctly. Not only does this technology let you perform your job effortlessly, but it also will also provide opportunities to participate in utility and state certified programs where you and your customers may be elligible for rebates.
As the World’s Largest Supplier of Diagnostic Verification Technology, Enalasys can provide you with a customized solution to fit your needs.
Because we care about your success, we also offer training opportunities and ongoing support that will prepare you and your business for success.
VST Base Setup
Verification Service Technology
- Large/Pressure Data Collection Unit (DCU)
- Radio/Receiver
- Cables-USB/DB9
- Software
The use of the eScan VST Base™ System can be used in most utility, state and federal programs in the United States and Canada
Overview
The Large pressure Data Collection Unit including software and the Radio/Receiver are the only requlred components to perform diagnostic tests with Enalasys if a contractor owns a laptop and other compatible diagnostic tools like a DuctBlaster®.
The Radio/Receiver connects to the back of the laptop via a usb cable, and communicates with the large data collection unit (DCU) which is connected to a compatible computerized digital sensor. If the user decides he or she would like to be able to perform various diagnostic testing, additional components will be necessary.
For example: If you would like to diagnose duct leakage, a duct blaster would need to be purchased. This diagnostic tool measures the charge rite along with duct testing an additional purchase will need to be made. The contractor will need to purchase the AHDCU with probes and Pressure harness which attaches to his Large/Pressure DCU. Any additional upgrades would include flow hoods & Remote DCU.
The VST Base qualifies for the State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing as well as many other participating states.
-
eScan | ChargeRite™
(RCA) Fastest Charging System on the Market
VST Base Setup (Verification Service Technology):
- Large/Pressure DCU
- Radio/Receiver
- Cables-USB/DB9
- Software
- Laptop Computer
- Patented Probes (2)
- Pressure Harness
- Portable Bubble Jet Printer (not shown)
- Carrying Case (not shown)
Overview
Great starter package to get your business going.
With the ChargeRite Pro™, technicians can now properly diagnose and charge air conditioners with the correct amount of refrigerant levels.
The Pressure Data Collection Unit connects to the laptop and collects outdoor conditions and measurements at the condensing/outdoor unit, including temperatures and pressures.
A set of two probes contain temperature sensors, humidity sensors, and pressure sensors to collect and measure conditions in the return plenum and supply plenum. Each probe also has a pressure sensor to measure the condition outside of the air handler.
Programs
The use of the eScan ChargeRite™ System can be used in:
State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing
Air Conditioner Measures
- Improved Refrigerant Charge
- Installation of TXV
- Adequate Air Flow
- Air Handler Fan Watt Draw (Also requires Portable Watt Meter)
- High EER
- Maximum Cooling Capacity
Utility Programs
- Air flow and Refrigerant Charge
Any additional programs similar to CA Title 24 Air Conditioner Measures
-
eScan | ChargeRite Pro™
(RCA) Fastest Charging System on the Market
VST Base Setup (Verification Service Technology):
- Large/Pressure DCU
- Radio/Receiver
- Cables-USB/DB9
- Software
- Laptop Computer
- Patented Probes (2)
- Pressure Harness
- TrueFlow® Meter (see below)
- Portable Bubble Jet Printer (not shown)
- Carrying Case (not shown)
Overview
With the ChargeRite Pro™, technicians can properly diagnose and charge air conditioners with the correct amount of refrigerant levels.
The Pressure Data Collection Unit connects to the laptop and collects outdoor conditions and measurements at the condensing/outdoor unit, including temperatures and pressures.
A set of two probes contain temperature sensors, humidity sensors, and pressure sensors to collect and measure conditions in the return plenum and supply plenum. Each probe also has a pressure sensor to measure the condition outside of the air handler.
The use of the eScan ChargeRite™ System can be used in:
State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing
Air Conditioner Measures
- Improved Refrigerant Charge
- Installation of TXV
- Adequate Air Flow
- Air Handler Fan Watt Draw (Also requires Portable Watt Meter)
- High EER
- Maximum Cooling Capacity
Utility Programs
- Air flow and Refrigerant Charge
Any additional programs similar to CA Title 24 Air Conditioner Measures
TrueFlow® Air Handler Flow Meter by Energy Conservatory
- Designed to provide a simple and accurate measurement of airflow through residential air handlers.
- The TrueFlow Meter temporarily replaces the filter in the air handler distribution system during the airflow measurement process.
- If the filter location is directly adjacent to the air handler, the TrueFlow Meter will measure the total air handler flow.
- If the filter is located remotely at a central return, the TrueFlow Meter will measure airflow through the central return.
-
eScan | DuctTite™
(DTS) Diagnose Air Ducts for Potential Leakage.
What is included:
- VST Base Setup (Verification Service Technology)
- Large/Pressure DCU
- Radio/Receiver
- Cables-USB/DB9
- Software
- DuctBlaster® by Energy Conservatory (see below)
- A digital camera is not included, but recommended to document condition of distribution system.
Overview
VST Base Equipment Overview
The two components needed for operating the eScan software and use of the
verification services are the two components listed above and applicable cables. This is all a contractor needs from Enalasys if he has his own laptop and other compatible diagnostic tools like a duct blaster.The Radio/Receiver connects to the back of the laptop via a usb cable, and communicates with the large data collection unit (DCU) which is connected to a compatible computerized digital sensor. If the user decides he or she would like to be able to perform various diagnostic testing additional components will be necessary.
An example would be if the user wants to diagnose duct leakage a duct blaster would need to be purchased. measures the charge rite along with duct testing an additional purchase will need to be made. The contractor will need to purchase the AHDCU with probes and Pressure harness which attaches to his Large/Pressure DCU. Any additional upgrades would include flow hoods & Remote DCU.
eScan Base qualifies for the State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing and many other states ask for details.
Programs
The use of the eScan DuctTite™ would meet the testing equipment requirements for installation and/or field verification for the following programs:
State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing
- Duct Measures
- Duct Sealing
- Air Conditioner Measures
- Installation of TXV
Utility Programs: Duct Leakage and Seal
Any additional programs similar to CA Title 24 as listed above.
Duct Blaster®
- A lightweight Duct Blaster fan weighs just 7 pounds, but delivers enough air flow (an amazing 1,500 CFM) to test even the leakiest of duct systems
- Quick and accurate air tightness measurements from 20 - 1,500 CFM. Compatible for both pressurization and depressurization testing. Compatible for both pressurization and depressurization testing.
- The Duct Blaster can be easily used in new construction applications where a Blower Door can't be used (e.g. before sheet rock is installed).
- The Duct Blaster can also be used as a powered flow hood to accurately measure air flows through the air handler fan, registers and grilles, and exhaust fans.
- It incorporates a variable fan speed control (solid state) available for both 110V and 220V models and a data collection module for communication with and control by the laptop.
- Includes a padded nylon carrying case with shoulder strap.
-
eScan | DuctRite™
A complete solution to diagnosing duct leakage, refrigerant charge.
- VST Base Setup (Verification Service Technology)
- Large/Pressure DCU
- Radio/Receiver
- Cables-USB/DB9
- Software
- Laptop Computer
- Patented Probes (2)
- Pressure Harness
- TrueFlow® Meter (see below)
- Bubble Jet Printer (not shown)
- Carrying Case (not shown)
- DuctBlaster® by Energy Conservatory
- DG700
- Smoke Generator (Optional)
- Digital Camera not included but recommended.
Overview
The DuctRite™ System includes the ChargeRIte and DuctTite Equipment in one complete package. All the items listed above are included in the package.
Programs
State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing
Duct Measures:
- Duct Sealing
- Supply Duct Location, Surface Area and R-factor
Air Conditioner Measures:
- Improved Refrigerant Charge
- Installation of TXV
- Adequate Air Flow
- Air Handler Fan Watt Draw (Also requires Portable Watt Meter)
- High EER
- Maximum Cooling Capacity
Building Envelop Measures:
- High Quality Insulation Installation
Utility Programs:
- Air flow and Refrigerant Charge
- Any additional programs similar to CA Title 24 as listed above
EPA Energy Star field verification for New ENERGY STAR® Residential Air-Source Heat Pumps and Central Air Conditioners.
Duct Blaster®
- A lightweight Duct Blaster fan weighs just 7 pounds, but delivers enough air flow (an amazing 1,500 CFM) to test even the leakiest of duct systems
- Quick and accurate air tightness measurements from 20 - 1,500 CFM. Compatible for both pressurization and depressurization testing. Compatible for both pressurization and depressurization testing.
- The Duct Blaster can be easily used in new construction applications where a Blower Door can't be used (e.g. before sheet rock is installed).
- The Duct Blaster can also be used as a powered flow hood to accurately measure air flows through the air handler fan, registers and grilles, and exhaust fans.
- It incorporates a variable fan speed control (solid state) available for both 110V and 220V models and a data collection module for communication with and control by the laptop.
- Includes a padded nylon carrying case with shoulder strap.
TrueFlow® Air Handler Flow Meter by Energy Conservatory
- Designed to provide a simple and accurate measurement of airflow through residential air handlers.
- The TrueFlow Meter temporarily replaces the filter in the air handler distribution system during the airflow measurement process.
- If the filter location is directly adjacent to the air handler, the TrueFlow Meter will measure the total air handler flow.
- If the filter is located remotely at a central return, the TrueFlow Meter will measure
-
eScan | AirRite™
Scaled Down Version of the eScan Pro
- 2 Wireless Data Collection Units (DCU)
- VST Base Setup: The base station includes: a laptop computer, proprietary software, transceiver, color printer and applicable cables.
- One extra optional AirFlow Hood one for supply registers (with two skirts), one for return grilles, one small or one large.
- Includes two extension poles (1-long and 1-Short). All equipment comes in durable blue nylon bags.
Capabilities
- Verify that the space conditioning equipment meets the heating load calculations
- Introduce homeowners to the use of diagnostic testing equipment
- Qualify if there are leaks in the distribution system, and generate further diagnostic testing opportunities with the homeowner
-
eScan | Pro™
- 6 Wireless data Collection Units (DCU) and one base station
- Four patented DCU Airflow Hoods -- one for supply registers (with two skirts), two for return grilles (one small and one large) and one for the condensing / outdoor unit. A fifth DCU (Pressure Unit) collects outdoor conditions and measurements at the condensing / outdoor unit, including temperatures and pressures.
- The sixth DCU (Remote) measures ambient conditions in the attic or crawl space.
- The base station includes a laptop computer, proprietary software, transceiver, color printer and applicable cables. Includes three extension poles (2-long and 1-Short) and Data collection Probes for Air Handler. All equipment comes in durable blue nylon bags.
Programs
The use of the eScan Pro™ would meet the testing equipment requirements for installation and/or field verification for the following programs:
State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing
Air Conditioner Measures:
- Improved Refrigerant Charge
- Installation of TXV
- Adequate Air Flow
- Air Handler Fan Watt Draw (Also requires Portable Watt Meter)
- High EER
- Maximum Cooling Capacity
Utility Programs:
- Air flow and Refrigerant Charge
- Any additional programs similar to CA Title 24 Air Conditioner Measures
EPA Energy Star field verification for New ENERGY STAR® Residential Air-Source Heat Pumps and Central Air Conditioners.
-
eScan | HomeRite™
Complete collection of diagnostic testing equipment and verification software and hardware to produce results.
Includes the following:
- eScan Pro™
- eScan ChargeRIte™
- DuctBlaster®
- TrueFlow Meter®
- Blower Door & DG700
- Smoke Generator (Optional)
- Digital Camera (Optional)
Overview
This sophisticated combination of equipment is your complete solution to checking HVAC units and duct systems for efficiency problems.
Programs
The use of the eScan HomeRite™ would meet the testing equipment requirements for installation and/or field verification for the following programs:
State of California Title 24 Measures Requiring Field Verification and Diagnostic Testing
Duct Measures:
- Duct Sealing
- Supply Duct Location, Surface Area and R-factor
Air Conditioner Measures:
- Improved Refrigerant Charge
- Installation of TXV
- Adequate Air Flow
- Air Handler Fan Watt Draw (Also requires
- Portable Watt Meter)
- High EER
- Maximum Cooling Capacity
Building Envelop Measures:
- Building Envelope Sealing
- High Quality Insulation Installation
Utility Programs:
- Air flow and Refrigerant Charge
- Any additional programs similar to CA Title 24 as listed above
EPA Energy Star field verification for New ENERGY STAR® Residential Air-Source Heat Pumps and Central Air Conditioners (Projected to be effective March 2006. California Building Performance Contractors Association and U.S. EPA Home Performance with Energy Star Program for existing homes.
Duct Blaster®
- A lightweight Duct Blaster fan weighs just 7 pounds, but delivers enough air flow (an amazing 1,500 CFM) to test even the leakiest of duct systems
- Quick and accurate air tightness measurements from 20 - 1,500 CFM. Compatible for both pressurization and depressurization testing. Compatible for both pressurization and depressurization testing.
- The Duct Blaster can be easily used in new construction applications where a Blower Door can't be used (e.g. before sheet rock is installed).
- The Duct Blaster can also be used as a powered flow hood to accurately measure air flows through the air handler fan, registers and grilles, and exhaust fans.
- It incorporates a variable fan speed control (solid state) available for both 110V and 220V models and a data collection module for communication with and control by the laptop.
- Includes a padded nylon carrying case with shoulder strap.
TrueFlow® Air Handler Flow Meter by Energy Conservatory
- Designed to provide a simple and accurate measurement of airflow through residential air handlers.
- The TrueFlow Meter temporarily replaces the filter in the air handler distribution system during the airflow measurement process.
- If the filter location is directly adjacent to the air handler, the TrueFlow Meter will measure the total air handler flow.
- If the filter is located remotely at a central return, the TrueFlow Meter will measure
Blower Door®
- Our Blower Door facilitates tests to gauge the air tightness levels of building envelopes.
- It is utilized to diagnose and demonstrate air leakage problems, estimate natural infiltration rates, estimate efficiency losses from that air leakage, and to certify construction integrity.
- The Blower Door enables precise, stable flow measurements without the need for gauge dampening.
- Quick and accurate flow measurements from 30 to 6,300 CFM. It consists of a lightweight, rugged injection molded fan housing with and a variable fan speed control (solid state) in both 110V/60 Hz and 220V/50 Hz models (CE labeling available for 220V model) as well as a data collection module for communication with and control by the eScan laptop.
DG-700
Digital pressure and flow gauge is the latest instrumentation option for the Model 3 Blower Door.
The DG-700 contains 2 precision pressure sensors which provide simultaneous display of both building pressure and Blower Door fan flow readings.
It's specialized "Baseline" and "CFM @50" features makes it extremely easy to get quick and accurate airtightness test results.
In addition, the DG-700 can be used along with a laptop computer and specialized TEC software to conduct fully automated Blower Door tests.